Menu
0
Total price
0 €
PRICES include / exclude VAT
>ASTM C0956-24 - Standard Specification for Installation of Cast-In-Place Reinforced Gypsum Concrete
Vydáno: 01.05.2024

ASTM C0956-24

Standard Specification for Installation of Cast-In-Place Reinforced Gypsum Concrete

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
Non-printable
62.71 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
74.90 €
Anglicky Hardcopy
In stock
62.71 €
Označení normy:ASTM C0956-24
Vydáno:01.05.2024
Status:Active
Počet stran:7
Sekce:04.01
Označení:calculation of diaphragm shear; gypsum concrete; gypsum roof deck ;
ASTM označení:ASTM C956
Nahrazuje:C0956-04R19

This specification covers the minimum requirements for the installation of cast-in-place reinforced gypsum concrete over permanent formboard. Subpurlins shall be designed to support live and dead loads of the roof deck. Got-rolled and cold-rolled steel shapes other than bulb trees or truss tees shall meet the requirements of this specification. Mineral fiber formborad shall be tested in accordance with the transverse loading test. Hexagonal reinforcing mesh, rectangular reinforcing fabric, gypsum concrete, and expansion filler strip shall be fabricated in accordance to the specification. The subpurlins shall be placed transversely to the purlins and primary framing and shall be spaced to suit the size of the formboards. Cross tees shall be provided where formboard ends are supported by purlins or the primary framing. Formboards shall be located face down on the flanges of the supporting members and with the ends on top of the purlins. The mesh of wire fabric shall be located with the main longitudinal wires at right angles to the subpurlins and adjacent to the formboard at midspan between the purlins. Expansion filler strips shall be placed continuously against the walls, curbs, nailers, or other rigid surfaces that gypsum concrete will abut. Gypsum concrete mixing and placement shall be performed. Mixing shall be thorough but not overmixed.

DESCRIPTION

1.1 This specification covers the minimum requirements for the installation of cast-in-place reinforced gypsum concrete over permanent formboard.

1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered requirements of the standard.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Související produkty
Anglicky Secure PDF
Immediate download
Non-printable
55.74 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
67.06 €
Anglicky Hardcopy
In stock
55.74 €
Anglicky Secure PDF
Immediate download
Non-printable
55.74 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
67.06 €
Anglicky Hardcopy
In stock
55.74 €
Anglicky Secure PDF
Immediate download
Non-printable
69.67 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
83.61 €
Anglicky Hardcopy
In stock
69.67 €
Anglicky Secure PDF
Immediate download
Non-printable
62.71 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
74.90 €
Anglicky Hardcopy
In stock
62.71 €
Anglicky Secure PDF
Immediate download
Non-printable
90.58 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
108.87 €
Anglicky Hardcopy
In stock
90.58 €
Anglicky Secure PDF
Immediate download
Non-printable
69.67 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
83.61 €
Anglicky Hardcopy
In stock
69.67 €