Menu
0
Total price
0 €
PRICES include / exclude VAT
>ASTM D7315-17R23 - Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode
Vydáno: 01.11.2023

ASTM D7315-17R23

Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
Non-printable
88.25 €
Anglicky Hardcopy
In stock
88.25 €
Označení normy:ASTM D7315-17R23
Vydáno:01.11.2023
Status:Active
Počet stran:22
Sekce:11.01
Označení:calibration; calibration turbidity standard; calibration verification; measurement; nephelometric turbidity; ratio turbidity; turbidimeter; turbidity; turbidity standards;
ASTM označení:ASTM D7315
Nahrazuje:D7315-17
DESCRIPTION

1.1 This test method covers the static determination of turbidity in water. Static refers to a sample that is removed from its source and tested in an isolated instrument. (See Section 4.)

1.2 This test method is applicable to the measurement of turbidities greater than 1.0 turbidity unit (TU). The upper end of the measurement range was left undefined because different technologies described in this test method can cover very different ranges. The round robin study covered the range of 0 to 4000 turbidity units because instrument verification in this range can typically be covered by standards that can be consistently reproduced.

1.3 Many of the turbidity units and instrument designs covered in this test method are numerically equivalent in calibration when a common calibration standard is applied across those designs listed in Table 1. Measurement of a common calibration standard of a defined value will also produce equivalent results across these technologies.

1.3.1 In this test method calibration standards are often defined in NTU values, but the other assigned turbidity units, such as those in Table 1 are equivalent. For example, a 1 NTU formazin standard is also a 1 FNU, a 1 FAU, a 1 BU, and so forth.

1.4 This test method does not purport to cover all available technologies for high-level turbidity measurement.

1.5 This test method was tested on different natural waters and wastewater, and with standards that will serve as surrogates to samples. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

1.6 Depending on the constituents within a high-level sample, the proposed sample preparation and measurement methods may or may not be applicable. Those samples with the highest particle densities typically prove to be the most difficult to measure. In these cases, and alternative measurement method such as the process monitoring method can be considered.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this procedure.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Související produkty
Anglicky Secure PDF
Immediate download
Non-printable
88.25 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
106.07 €
Anglicky Hardcopy
In stock
88.25 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
81.46 €
Anglicky Hardcopy
In stock
67.88 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
81.46 €
Anglicky Hardcopy
In stock
67.88 €
Anglicky Secure PDF
Immediate download
Non-printable
111.16 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
133.22 €
Anglicky Hardcopy
In stock
111.16 €
Anglicky Secure PDF
Immediate download
Non-printable
61.10 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
72.98 €
Anglicky Hardcopy
In stock
61.10 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Hardcopy
In stock
67.88 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Hardcopy
In stock
67.88 €
Anglicky Secure PDF
Immediate download
Non-printable
88.25 €
Anglicky Hardcopy
In stock
88.25 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Hardcopy
In stock
67.88 €
Anglicky Secure PDF
Immediate download
Non-printable
88.25 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
106.07 €
Anglicky Hardcopy
In stock
88.25 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Hardcopy
In stock
67.88 €
Anglicky Secure PDF
Immediate download
Non-printable
54.31 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
65.34 €
Anglicky Hardcopy
In stock
54.31 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
81.46 €
Anglicky Hardcopy
In stock
67.88 €
Anglicky Secure PDF
Immediate download
Non-printable
67.88 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
81.46 €
Anglicky Hardcopy
In stock
67.88 €