>ASTM D8322-25 - Standard Test Method for Determination of Elements in Residual Fuels and Crude Oils by Microwave Plasma Atomic Emission Spectroscopy (MP-AES)
Vydáno: 01.07.2025

ASTM D8322-25

Standard Test Method for Determination of Elements in Residual Fuels and Crude Oils by Microwave Plasma Atomic Emission Spectroscopy (MP-AES)

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
Non-printable
68.33 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
81.99 €
Anglicky Hardcopy
In stock
68.33 €
Označení normy:ASTM D8322-25
Vydáno:01.07.2025
Status:Active
Počet stran:11
Sekce:05.05
Označení:calcium; crude oil; emission-spectrometry; iron; microwave plasma atomic emission spectroscopy; MP-AES; nickel; potassium; sodium; vanadium;
DESCRIPTION

1.1 This test method covers the determination of metals and other elements in residual fuel and crude oil by microwave plasma atomic emission spectroscopy (MP-AES). The specific elements within the scope of this method are V, Ni, Ca, Na, Al, Si, Zn, P, and S for residual fuel oil and Fe, V, Ni, Ca, Na, K, and S for crude oils.

1.2 Method working range:
high expected concentration limit = highest ILS sample mean
low expected concentration limit = lowest ILS sample mean if:

(1) lowest ILS sample mean − Rlowest ILS sample mean > 0; otherwise it is determined by solving for X using the following equation:

(2) X − RX= coarsest resolution, determined by
0.5*σr lowest ILS sample mean

Crude Oil:

Element

Method Working Range

(expected mg/kg)

Iron

0.70 to 161.02

Vanadium

2.88 to 417.50

Nickel

0.36 to 107.66

Calcium

5.41 to 96.78

Sodium

1.18 to 97.13

Potassium

7.01 to 63.83

Sulfur

1059 to 35194

Residual Fuel Oil:

Element

Method Working Range

(expected mg/kg)

Vanadium

3.88 to 370.09

Nickel

1.47 to 96.68

Calcium

4.41 to 102.01

Sodium

2.80 to 112.67

Aluminum

4.13 to 154.12

Silicon

5.99 to 237.56

Zinc

2.75 to 102.46

Sulfur

1314 to 30134

1.3 This test method uses soluble metals in organic solvents for calibration and does not purport to quantitatively determine insoluble particulates. Analytical results are particle size dependent, and particles larger than a few micrometers may cause results to appear low

1.4 Elements present at mass fractions above the upper limit of the calibration curves can be determined with additional appropriate dilutions. Elements shall be measured at the wavelengths presented in Table 1.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.