>ASTM E2823-25 - Standard Test Method for Analysis of Nickel Alloys by Inductively Coupled Plasma Mass Spectrometry (Performance-Based)
Vydáno: 01.11.2025

ASTM E2823-25

Standard Test Method for Analysis of Nickel Alloys by Inductively Coupled Plasma Mass Spectrometry (Performance-Based)

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
Non-printable
61.10 €
Anglicky Secure PDF Redline
Immediate download
Non-printable
72.98 €
Anglicky Hardcopy
In stock
61.10 €
Označení normy:ASTM E2823-25
Vydáno:01.11.2025
Status:Active
Počet stran:8
Sekce:03.05
Označení:ICP-MS; inductively coupled plasma mass spectrometry; nickel; nickel alloys;
ASTM označení:ASTM E2823
Nahrazuje:E2823-17
DESCRIPTION

1.1 This test method describes the inductively coupled plasma mass spectrometric analysis of nickel and nickel alloys, as specified by Committee B02, and having chemical compositions within the following limits:

Element

Application Range (Mass Fraction %)

Aluminum

0. 01–6.00

Boron

0. 01–0.10

Carbon

0. 01–0.15

Chromium

0. 01–33.00

Copper

0.01–35.00

Cobalt

0. 01–20.00

Iron

0.05–50.00

Magnesium

0. 01–0.020

Molybdenum

0. 01–30.0

Niobium

0. 01–6.0

Nickel

25.00–100.0

Phosphorous

0.001–0.025

Silicon

0.01–1.50

Sulfur

0.0001–0.01

Titanium

0.0001–6.0

Tungsten

0.01–5.0

Vanadium

0.0005–1.0

1.2 The following elements may be determined using this method.

Element

Quantification Range (μg/g)

Antimony

0.5–50

Bismuth

0.1–11

Gallium

2.9–54

Lead

0.4–21

Silver

1–35

Tin

2.2–97

Thallium

0.5–3.0

1.3 This method has only been interlaboratory tested for the elements and ranges specified. It may be possible to extend this method to other elements or different composition ranges provided that method validation that includes evaluation of method sensitivity, precision, and bias as described in this document is performed. Additionally, the validation study must evaluate the acceptability of sample preparation methodology using reference materials or spike recoveries, or both. The user is cautioned to carefully evaluate the validation data as to the intended purpose of the analytical results. Guide E2857 provides additional guidance on method validation.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific safety hazard statements are given in Section 9.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.