Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 17671:2025 Heating systems and water-based cooling systems in buildings. Design for water-based cooling systems
sklademVydáno: 2025-08-26
BS EN 17671:2025 Heating systems and water-based cooling systems in buildings. Design for water-based cooling systems

BS EN 17671:2025

Heating systems and water-based cooling systems in buildings. Design for water-based cooling systems

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
307.58 €
Anglicky Hardcopy
In stock
307.58 €
Označení normy:BS EN 17671:2025
Počet stran:40
Vydáno:2025-08-26
ISBN:978 0 539 28438 6
Status:Standard
Počet stran (Anglicky):40
ISBN (Anglicky):978 0 539 28438 6
DESCRIPTION

BS EN 17671:2025


This standard BS EN 17671:2025 Heating systems and water-based cooling systems in buildings. Design for water-based cooling systems is classified in these ICS categories:
  • 91.140.30 Ventilation and air-conditioning systems
This document specifies design criteria for closed water-based cooling systems in buildings and the design of such systems is described. The definitions are aimed at achieving an appropriate level of technical quality and maintaining the desired thermal indoor climate with minimum energy consumption. This document does not apply to systems for dissipating process heat from industrial processes. It also does not apply to and does not amend product standards or product installation requirements. This document is applicable to cooling systems of the following type (see also Figure 1): 1) devices for the water-based heat rejection of the chilling system; 2) devices for chilling and storage of chilled water; 3) devices for the distribution of chilled water; 4) devices for the absorption of heat ("cooling emission"); 5) control devices; 6) safety devices. Figure 1 - Schematic example of a water-based cooling system This document does not cover additional safety aspects for water-based cooling systems with local operating temperatures ≤ 0 °C. The other clauses of this document are still valid for systems with local operating temperatures ≤ 0 °C. This document also does not cover the chilling system itself, but only the parts of the chilling system which are an integral part of the cooling system, including determination of the design performance. Furthermore, this document does not cover: - the requirements for installation or instructions for operation, maintenance and use; - the design of the system components (e.g. recooler, chilling system, coolers, pipes, safety devices etc.).