>IEC 61788-15:2026 - Superconductivity - Part 15: Electronic characteristic measurements - Intrinsic surface impedance of superconductor films at microwave frequencies
sklademVydáno: 2026-03-23

IEC 61788-15:2026

Superconductivity - Part 15: Electronic characteristic measurements - Intrinsic surface impedance of superconductor films at microwave frequencies

Supraconductivité - Partie 15 : Mesurages des caractéristiques électroniques - Impédance de surface intrinsèque de films supraconducteurs aux fréquences micro-ondes

Format
Availability
Price and currency
Anglicky/Francouzsky Hardcopy
skladem
442.60 €
Anglicky PDF
Immediate download
Printable
442.60 €
Anglicky Hardcopy
skladem
442.60 €
View table of Contents
Označení normy:IEC 61788-15:2026
Vydáno:2026-03-23
Edice:2
ICS:17.220.20
Počet stran (Anglicky):62
ISBN (Anglicky):9782832711132
DESCRIPTION

IEC 61788-15:2026

IEC 61788-15:2026 describes measurements of the intrinsic surface impedance (Zs) of HTS films at microwave frequencies by a modified two-resonance mode dielectric resonator method. The object of measurement is to obtain the temperature dependence of the intrinsic Zs at the resonant frequency f0.
The frequency and thickness range and the measurement resolution for the Zs of HTS films are as follows:
- frequency: up to 40 GHz;
- film thickness: greater than 50 nm;
- measurement resolution: 0,01 mΩ at 10 GHz.
It is crucial that the Zs data at the measured frequency, and that scaled to 10 GHz be reported for comparison, assuming the f2 rule for the intrinsic surface resistance, Rs (f < 40 GHz), and the f rule for the intrinsic surface reactance, Xs. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- informative Annex B, combined relative standard uncertainty in the intrinsic surface impedance is added;
- the terms, ‘precision and accuracy’, are replaced with uncertainty;
- results from a round robin test are added.