Menu
0
Total price
0 €
PRICES include / exclude VAT
>UNE EN 16798-7:2019 - Energy performance of buildings - Ventilation for buildings - Part 7: Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5)
sklademVydáno: 2019-10-02
UNE EN 16798-7:2019 - Energy performance of buildings - Ventilation for buildings - Part 7: Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5)

UNE EN 16798-7:2019

Energy performance of buildings - Ventilation for buildings - Part 7: Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5)

Eficiencia energética de los edificios. Ventilación de los edificios. Parte 7: Métodos de cálculo para determinar los caudales de aire en los edificios incluidas las infiltraciones (Módulo M5-5).

Format
Availability
Price and currency
Anglicky PDF
Immediate download
Printable
140.63 €
Anglicky Hardcopy
In stock
140.63 €
Španělsky PDF
Immediate download
Printable
140.63 €
Španělsky Hardcopy
In stock
140.63 €
Označení normy:UNE EN 16798-7:2019
Počet stran:62
Vydáno:2019-10-02
Status:Norma
Počet stran (Španělsky):69
DESCRIPTION

UNE EN 16798-7:2019

This European Standard describes the methods to calculate the ventilation air flow rates for buildings to be used for energy calculations evaluation, heating and cooling loads. This European Standard applies to buildings with: ¾ð Mechanical ventilation systems (mechanical exhaust, mechanical supply or balanced system); ¾ð Passive duct ventilation systems for residential and low-rise non-residential buildings; ¾ð Combustion appliances; ¾ð Windows opening by manual operation; ¾ð Kitchens where cooking is for immediate use (including restaurants) This European Standard is applicable to hybrid systems combining mechanical and passive duct ventilation systems in residential and low-rise non-residential buildings. This European Standard applies to buildings smaller than 100 m and rooms where vertical air temperature difference is smaller than 15 K. The results provided by the standard are: ¾ð the air flow rates entering or leaving a ventilation zone; ¾ð the air flow rates required to be distributed by the mechanical ventilation system, if present. This European Standard is not applicable to: ¾ð Buildings with kitchens where cooking is not for immediate use ¾ð Buildings with automatic windows (or openings) ¾ð Buildings with industry process ventilation. The definition of ventilation and airtightness requirements (as indoor air quality, heating and cooling, safety, fire protection& ) is not covered by this standard. The following information can be found in other standards and technical reports: ¾ð guidance to estimate pressure drops in ducts (CR 14378:2002) Table 1 shows the relative position of this standard within the EN EPB package of standards.

Categories: