UNE EN 50522:2022
Earthing of power installations exceeding 1 kV a.c.
Puesta a tierra en instalaciones eléctricas de tensión superior a 1 kV en corriente alterna.
| Označení normy: | UNE EN 50522:2022 |
| Počet stran: | 80 |
| Vydáno: | 2022-11-02 |
| Status: | Norma |
| Počet stran (Španělsky): | 91 |
UNE EN 50522:2022
This document is applicable to specify the requirements for the design and erection of earthing systems of electrical installations, in systems with nominal voltage above 1 kV AC and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended. NOTE 1 The technical and procedural principles of this document can be applied when 3rd parties installations and facilities are planned and/or erected in the vicinity of HV electrical power installations. For the purpose of interpreting this document, an electrical power installation is considered to be one of the following: a) substation, including substation for railway power supply; b) electrical power installations on mast, pole and tower; switchgear and/or transformers located outside a closed electrical operating area; c) one (or more) power station(s) located on a single site; the electrical power installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded; d) the electrical system of a factory, industrial plant or other industrial, agricultural, commercial or public premises; e) electrical power installations on offshore facilities for the purpose of generation, transmission, distribution and/or storage of electricity; f) transition towers/poles between overhead lines and underground lines. The electrical power installation includes, among others, the following equipment: rotating electrical machines; switchgear; transformers and reactors; converters; cables; wiring systems; batteries; capacitors; earthing systems; buildings and fences which are part of a closed electrical operating area; associated protection, control and auxiliary systems; large air core reactor. NOTE 2 In general, a standard for an item of equipment takes precedence over this document. This document does not apply to the design and erection of earthing systems of any of the following: overhead and underground lines between separate installations; NOTE 3 The standard, EN 50341 series Overhead lines exceeding AC 1 kV, specifies requirements for the design and erection of earthing systems in overhead lines. electrified railway tracks and rolling stock; mining equipment and installations; fluorescent lamp installations; installations on ships and off-shore installations; electrostatic equipment (e.g. electrostatic precipitators, spray-painting units); test sites; medical equipment, e.g. medical X-ray equipment. NOTE 4 The scope of this document does not include the requirements for carrying out live working on electrical power installations. NOTE 5 The scope of this document considers safety requirements for HV installations and its influences on LV installations. For electrical installation up to 1 kV, the standard IEC 60364 series applies.