Menu
0
Total price
0 €
PRICES include / exclude VAT
>UNE EN IEC 61869-11:2019 - Instrument transformers - Part 11: Additional requirements for low-power passive voltage transformers
sklademVydáno: 2019-04-17
UNE EN IEC 61869-11:2019 - Instrument transformers - Part 11: Additional requirements for low-power passive voltage transformers

UNE EN IEC 61869-11:2019

Instrument transformers - Part 11: Additional requirements for low-power passive voltage transformers

Transformadores de medida. Parte 11: Requisitos adicionales para los transformadores de tensión pasivos de baja potencia.

Format
Availability
Price and currency
Anglicky PDF
Immediate download
Printable
106.80 €
Anglicky Hardcopy
In stock
106.80 €
Španělsky PDF
Immediate download
Printable
106.80 €
Španělsky Hardcopy
In stock
106.80 €
Označení normy:UNE EN IEC 61869-11:2019
Počet stran:41
Vydáno:2019-04-17
Status:Norma
Počet stran (Španělsky):42
DESCRIPTION

UNE EN IEC 61869-11:2019

This part 11 of IEC 61869 is a product standard and covers only additional requirements for low-power passive voltage transformers (passive LPVT). The product standard for low-power passive voltage transformers is composed by the IEC 61869-1, in addition with IEC 61869-6 and this standard with specific requirements. This International Standard is applicable to newly manufactured low-power passive voltage transformers with analogue output having rated frequencies from 15 Hz to 100 Hz for use with electrical measuring instruments or electrical protective devices. This Standard covers low-power passive voltage transformers used for measurement or protection and low-power passive voltage transformers used for both measurement and protection. Low-power passive voltage transformers are based on the voltage divider principle. They can be built for example as resistive dividers, capacitive dividers or resistive-capacitive dividers. Low-power passive voltage transformers have analogue output only (for digital output or for technology using any kind of active electronic components refer to IEC 61869-7). Such low-power passive voltage transformers may include the secondary signal cable (transmitting cable). According to a general block diagram given in Figure 601 (IEC 61869-6), the low-power passive voltage transformers do not use an active primary converter (i.e. without any active electronic component); therefore, there is no need for primary power supply. Additionally, neither the secondary converter nor the secondary power supply is used. The general block diagram of a low-power passive voltage transformer is given in Figure 1101. The applied technology decides which part is necessary for the realization of a low-power passive voltage transformer, i.e. it is not necessary that transmitting cable or primary converter described in Figure 1101 are included in the low-power passive voltage transformer.

Categories: