21/30402416 DC
BS EN ISO 28921-1. Industrial valves. Isolating valves for low-temperature applications Part 1. Design, manufacturing and production testing
| Označení normy: | 21/30402416 DC |
| Počet stran: | 33 |
| Vydáno: | 2021-04-13 |
| Status: | Draft for Comment |
21/30402416 DC
This standard 21/30402416 DC BS EN ISO 28921-1. Industrial valves. Isolating valves for low-temperature applications is classified in these ICS categories:
- 23.060.01 Valves in general
This document specifies requirements for design, dimensions, material, fabrication and production testing of gate, globe, ball/plug and butterfly valve design types used as isolation valves and check valves for low-temperature applications.
This document covers isolation valves for use in low and cryogenic temperature service where the design low-temperature service is -50 °C down to –196 °C.
This document does not apply to valves for cryogenic services, designed in accordance with ISO 21011, used with cryogenic vessels.
Where the requirements of this document vary from those given in the valve product standards, the requirements of this document apply.
This document covers valves with body, bonnet, bonnet extension or cover made of metallic materials.
It covers valves of nominal sizes DN: 10; 15; 20; 25; 32; 40; 50; 65; 80; 100; 125; 150; 200; 250; 300; 350; 400; 450; 500; 600; 650; 700; 750; 800; 850; 900; 950; 1 000; 1 050; 1 200; 1 350; 1 400; 1 500; 1 600; 1 650; 1 800.
corresponding to nominal pipe sizes NPS: 3/8; 1/2; 3/4; 1; 11/4; 11/2; 2; 21/2; 3; 4; 5; 6; 8; 10; 12; 14; 16; 18; 20; 24; 26; 28; 30; 32; 34; 36; 38; 40; 42; 48; 54; 56; 60; 64; 66; 72,
and applies to pressure designations:
PN 16; 25; 40; 100; 160; 250; 400;
Class 150; 300; 600; 800; 900; 1 500; 2 500.
Not all type and size combination are available in all pressure ratings.
This document excludes testing for safety valves and control valves.