IEC 60951-3:2009
Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 3: Equipment for continuous high range area gamma monitoring
Centrales nucléaires de puissance - Instrumentation importante pour la sûreté - Surveillance des rayonnements pour les conditions accidentelles et post-accidentelles - Partie 3: Ensemble de surveillance locale en continu des rayonnements gamma à large gamme
| Označení normy: | IEC 60951-3:2009 |
| Vydáno: | 2009-06-29 |
| Jazyk: | Anglicky/Francouzsky |
IEC 60951-3:2009
IEC 60951-3:2009 provides general guidance on the design principles and performance criteria for equipment for continuous high range area gamma monitoring in nuclear power plants for accident and post-accident conditions. General requirements for technical characteristics, test procedures, radiation characteristics, electrical, mechanical, and environmental characteristics are given in IEC 60951-1. These requirements are applicable in this part unless otherwise stated. The main technical changes with regard to the previous edition are as follows: - clarify the definitions; - up-date the references to new standards published since the first edition; - update the units of radiation. This publication is to be read in conjunction with IEC 60951-1:2009.