>ISO/TR 15235:2001 - Preparation of steel substrates before application of paints and related products — Collected information on the effect of levels of water-soluble salt contamination
sklademVydáno: 2001-10-18
ISO/TR 15235:2001 - Preparation of steel substrates before application of paints and related products — Collected information on the effect of levels of water-soluble salt contamination

ISO/TR 15235:2001

ISO/TR 15235:2001 - Preparation of steel substrates before application of paints and related products — Collected information on the effect of levels of water-soluble salt contamination

Format
Availability
Price and currency
Anglicky PDF
Immediate download
Printable
159.38 €
Francouzsky PDF
Immediate download
Printable
159.38 €
Anglicky Hardcopy
In stock
159.38 €
Francouzsky Hardcopy
In stock
159.38 €
Označení normy:ISO/TR 15235:2001
Vydání:1
Vydáno:2001-10-18
Počet stran (Anglicky):24
Počet stran (Francouzsky):26
DESCRIPTION

ISO/TR 15235:2001

This Technical Report provides information on the effect of water-soluble chloride and sulfate contamination levels

on steel surfaces, before the application of paint or related products to surfaces prepared in accordance with

standard mechanical or blast-cleaning surface preparation methods.

NOTE The tolerance for water-soluble salt contamination may be different for different paint types.

This information may be used when evaluating the adequacy of surface preparation prior to painting.

This document is concerned only with measured levels of salt contamination based upon either laboratory or field

testing. The levels of soluble chloride and sulfate discussed in this document are to be compared using soluble

surface densities of the species as determined after extraction in accordance with ISO 8502-6 (the Bresle method),

or other methods giving equivalent results. Total soluble-salt contamination may be determined by conductometric

testing, but such testing will not determine the nature and concentration of the specific salts present, e.g. whether

chloride or sulfate is present, or its concentration.

This document does not define specific levels of cleanliness or methods of salt removal.