>UNE EN 1264-3:2022 - Water based surface embedded heating and cooling systems - Part 3: Dimensioning
sklademVydáno: 2022-02-16
UNE EN 1264-3:2022 - Water based surface embedded heating and cooling systems - Part 3: Dimensioning

UNE EN 1264-3:2022

Water based surface embedded heating and cooling systems - Part 3: Dimensioning

Sistemas de calefacción y refrigeración de circulación de agua integrados en superficies. Parte 3: Dimensionamiento.

Format
Availability
Price and currency
Anglicky PDF
Immediate download
Printable
87.60 €
Anglicky Hardcopy
In stock
87.60 €
Španělsky PDF
Immediate download
Printable
87.60 €
Španělsky Hardcopy
In stock
87.60 €
Označení normy:UNE EN 1264-3:2022
Počet stran:24
Vydáno:2022-02-16
Status:Norma
Počet stran (Španělsky):25
DESCRIPTION

UNE EN 1264-3:2022

EN 1264 covers surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commercial and industrial buildings) and focuses on systems installed for the purpose of thermal comfort. EN 1264 applies to water based heating and cooling systems embedded into the enclosure surfaces of the room to be heated or to be cooled. It also applies as appropriate to the use of other heating media instead of water. EN 1264 applies to identify standardized product characteristics by calculation and testing the thermal output of heating for technical specifications and certification. For the design, construction and operation of these systems, EN ISO 11855 applies. The systems covered in EN 1264 are adjoined to the structural base of the enclosure surfaces of the building, mounted directly or with fixing supports. It does not cover ceiling systems mounted in a suspended ceiling with a designed open air gap between the system and the building structure which allows the thermally induced circulation of the air. The thermal output of these systems can be determined according to ISO 18566, EN 14037 and EN 14240. EN 1264-3 deals with the use in practical engineering of the results coming from EN 1264-2 and EN 1264-5. For heating systems, physiological limitations are taken into account when specifying the surface temperatures. In the case of floor heating systems the limitations are realized by a design based on the characteristic curves and limit curves determined in accordance with EN 1264-2. For cooling systems, only a limitation with respect to the dew point is taken into account. In predominating practice, this means that physiological limitations are included as well.