Menu
0
Total price
0 €
PRICES include / exclude VAT
>UNE EN 16913:2018 - Ambient air - Standard method for measurement of NO3¯, SO4²¯, Cl¯, NH4+, Na+, K+, Mg²+, Ca²+ in PM2,5 as deposited on filters
sklademVydáno: 2018-02-28
UNE EN 16913:2018 - Ambient air - Standard method for measurement of NO3¯, SO4²¯, Cl¯, NH4+, Na+, K+, Mg²+, Ca²+ in PM2,5 as deposited on filters

UNE EN 16913:2018

Ambient air - Standard method for measurement of NO3¯, SO4²¯, Cl¯, NH4+, Na+, K+, Mg²+, Ca²+ in PM2,5 as deposited on filters

Aire ambiente. Método normalizado para la medición de NO3-, SO42-, Cl-, NH4+, Na+, K+, Mg2+, Ca2+ en PM 2,5 depositado en filtros.

Format
Availability
Price and currency
Anglicky PDF
Immediate download
Printable
121.20 €
Anglicky Hardcopy
In stock
121.20 €
Španělsky PDF
Immediate download
Printable
121.20 €
Španělsky Hardcopy
In stock
121.20 €
Označení normy:UNE EN 16913:2018
Počet stran:49
Vydáno:2018-02-28
Status:Norma
Počet stran (Španělsky):52
DESCRIPTION

UNE EN 16913:2018

This European Standard specifies a method for the determination of the mass concentration of water soluble NO3-, SO42-, Cl-, NH4+, Na+, K+, Mg2+, Ca2+ in PM2,5 as deposited on filters. This European Standard describes a measurement method which comprises sampling of anions and cations as part of the PM2,5 particulate phase, sample extraction and analysis of anions and cations by ion chromatography. NOTE 1 Alternatively, cations, excluding ammonium, can be analysed by inductively coupled plasma optical emission spectrometry (ICP-OES). Ammonium can also be analysed by photometry or conductometry. This European Standard can be used for the measurements of anions and cations as required by Directive 2008/50/EC. The method does not take into account the possible losses during sampling due to evaporation. NOTE 2 NO3-, Cl-, NH4+ are part of the volatile fraction of PM2,5, and the concentrations determined using this standard can be used as minimum values for the concentrations of these ions in PM2,5. NO3-, NH4+, Cl- are usually 0 % to 30 % underestimated due to evaporational losses from the filter during sampling. This European Standard may be used at rural and urban background sites and road sites that are in accordance with the siting criteria of Directive 2008/50/EC. This European Standard is applicable to the measurement of anion/cations in PM2,5 samples corresponding to mass concentrations between approximately 1 ¼g/m3 (i.e. the limit of detection of the standard measurement method (EN 12341) expressed as its uncertainty) up to 120 ¼g/m3.

Categories: