Menu
0
Total price
0 €
PRICES include / exclude VAT
>UNE EN 60034-12:2017 - Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors (Endorsed by Asociación Española de Normalización in July of 2017.)
sklademVydáno: 2017-07-01
UNE EN 60034-12:2017 - Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors (Endorsed by Asociación Española de Normalización in July of 2017.)

UNE EN 60034-12:2017

Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors (Endorsed by Asociación Española de Normalización in July of 2017.)

Maquinas eléctricas rotativas. Parte 12: Características de arranque de los motores trifásicos de inducción de jaula con una sola velocidad. (Ratificada por la Asociación Española de Normalización en julio de 2017.)

Format
Availability
Price and currency
Anglicky PDF
Immediate download
Printable
75.72 €
Anglicky Hardcopy
In stock
75.72 €
Označení normy:UNE EN 60034-12:2017
Počet stran:23
Vydáno:2017-07-01
Status:Norma
DESCRIPTION

UNE EN 60034-12:2017

This International standard specifies the parameters for eight designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034-1 that: " have a rated voltage up to 1 000 V; " are intended for direct-on-line or star-delta starting; " are rated on the basis of duty type S1; " are constructed to any degree of protection and explosion protection. The standard also applies to dual voltage motors provided that the flux saturation level is the same for both voltages. The values of torque, apparent power and current given in this standard are limiting values (that is, minimum or maximum without tolerance), NOTE 1 It is not expected that all manufacturers will produce machines for all eight designs. The selection of any specific design in accordance with this standard will be a matter of agreement between the manufacturer and the purchaser. NOTE 2 Designs other than the eight specified may be necessary for particular applications. NOTE 3 It should be noted that values given in manufacturers' catalogues may include tolerances in accordance with IEC 60034-1. NOTE 4 The values tabled for locked rotor apparent power are based on r.m.s. symmetrical steady state locked rotor currents; at motor switch on there will be a one-half cycle asymmetrical instantaneous peak current which may range from 1,8 to 2,8 times the steady state value. The current peak and decay time are a function of the motor design and switching angle.

Categories: