>ASTM F2102-17R26 - Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants
Vydáno: 01.01.2026

ASTM F2102-17R26

Standard Guide for Evaluating the Extent of Oxidation in Polyethylene Fabricated Forms Intended for Surgical Implants

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
Netisknutelné
1480 Kč
Anglicky Tisk
Skladem
1480 Kč
Označení normy:ASTM F2102-17R26
Vydáno:01.01.2026
Status:Active
Počet stran:5
Sekce:13.01
Označení:FTIR; implant; oxidation; oxidation index; UHMWPE;
ASTM označení:ASTM F2102
Nahrazuje:F2102-17
Popis

1.1 This guide covers a method for the measurement of the relative extent of oxidation present in HDPE homopolymers and ultra-high-molecular-weight polyethylene (UHMWPE) intended for use in medical implants. The material is analyzed by infrared spectroscopy. The intensity (area) of the carbonyl absorptions (>C=O) centered near 1720 cm–1 is related to the amount of chemically bound oxygen present in the material. Other forms of chemically bound oxygen (C-O-C, C-O-O-C, C-O-H, and so forth) are not captured by this guide.

1.2 Although this guide may give the investigator a means to compare the relative extent of carbonyl oxidation present in various UHMWPE samples, it is recognized that other forms of chemically bound oxygen may be important contributors to these materials' characteristics.

1.3 The applicability of the infrared method has been demonstrated by many literature reports. This particular method, using the intensity (area) of the C-H absorption centered near 1370 cm–1 to normalize for the sample’s thickness, has been validated by an interlaboratory study (ILS) conducted according to Practice E691.

Note 1: Note that both reagents effectively extracted the lipids (the lipid absorption peak is centered at approximately 1740 cm–1). The tibial insert was fabricated from highly crosslinked and remelted UHMWPE followed by terminal sterilization in EtO gas (Ref. 1).

1.4 The following precautionary caveat pertains only to the test method portion, Section 5, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Související produkty
Anglicky Zabezpečené PDF
K okamžitému stažení
Netisknutelné
1480 Kč
Anglicky Tisk
Skladem
1480 Kč
Anglicky Zabezpečené PDF
K okamžitému stažení
Netisknutelné
2137 Kč
Anglicky Zabezpečené PDF Redline
K okamžitému stažení
Netisknutelné
2569 Kč
Anglicky Tisk
Skladem
2137 Kč
Anglicky Zabezpečené PDF
K okamžitému stažení
Netisknutelné
1480 Kč
Anglicky Zabezpečené PDF Redline
K okamžitému stažení
Netisknutelné
1767 Kč
Anglicky Tisk
Skladem
1480 Kč
Anglicky Zabezpečené PDF
K okamžitému stažení
Netisknutelné
1315 Kč
Anglicky Zabezpečené PDF Redline
K okamžitému stažení
Netisknutelné
1583 Kč
Anglicky Tisk
Skladem
1315 Kč
Anglicky Zabezpečené PDF
K okamžitému stažení
Netisknutelné
1480 Kč
Anglicky Zabezpečené PDF Redline
K okamžitému stažení
Netisknutelné
1767 Kč
Anglicky Tisk
Skladem
1480 Kč
Anglicky Zabezpečené PDF
K okamžitému stažení
Netisknutelné
1480 Kč
Anglicky Zabezpečené PDF Redline
K okamžitému stažení
Netisknutelné
1767 Kč
Anglicky Tisk
Skladem
1480 Kč