Cena s DPH / bez DPH
>UNE EN 50647:2017 - Basic standard for the evaluation of workers' exposure to electric and magnetic fields from equipment and installations for the production, transmission and distribution of electricity (Endorsed by Asociación Española de Normalización in July of 2017.)
sklademVydáno: 2017-07-01
UNE EN 50647:2017 - Basic standard for the evaluation of workers' exposure to electric and magnetic fields from equipment and installations for the production, transmission and distribution of electricity (Endorsed by Asociación Española de Normalización in July of 2017.)

UNE EN 50647:2017

Basic standard for the evaluation of workers' exposure to electric and magnetic fields from equipment and installations for the production, transmission and distribution of electricity (Endorsed by Asociación Española de Normalización in July of 2017.)

Norma básica para la evaluación de la exposición de los trabajadores a los campos eléctricos y magnéticos de equipos e instalaciones para la generación, transmisión y distribución de electricidad (Ratificada por la Asociación Española de Normalización en julio de 2017.)

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
3033 Kč
Anglicky Tisk
Skladem
3033 Kč
Označení normy:UNE EN 50647:2017
Počet stran:56
Vydáno:2017-07-01
Status:Norma
Popis

UNE EN 50647:2017

This European Standard provides a general procedure to assess workers exposure to electric and magnetic fields (EMF) in work places associated with the production, transmission and distribution of electric energy, and to demonstrate compliance with exposure limit values and action levels as stated in the Council and European Parliament EMF Directive 2013/35/EU [10]. It has the role of a specific workplace standard. It takes into account the non-binding application guide for implementing the EMF Directive [9] and it defines the assessment procedures and compliance criteria applicable to the electric industry. The frequency range of this standard covers from DC to 20 kHz, which is sufficient to include the power frequency used for electric power supply systems throughout Europe (50 Hz) and the various harmonics and inter-harmonics occurring in the supply system. In this extremely low frequency range, electric and magnetic fields are independent and, therefore, they both have to be addressed in the exposure assessment. NOTE 1 Electrical companies also use radio frequency transmissions to operate and maintain their networks and power plants. Similarly, other exposures to EMF may occur during maintenance operations, for instance, due to the use of hand-held electrical tools. All these EMF sources are outside the scope of this standard. NOTE 2 Regarding EMF in the low frequency range, the scientific basis of the EMF directive is the ICNIRP health guidelines published in 2010 [12]. Reference is made to this scientific basis when necessary for justifying or clarifying some of the technical statements of the present document.

: