Cena s DPH / bez DPH
>UNE EN IEC 80601-2-71:2025 - Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment (Endorsed by Asociación Española de Normalización in April of 2025.)
sklademVydáno: 2025-04-01
UNE EN IEC 80601-2-71:2025 - Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment (Endorsed by Asociación Española de Normalización in April of 2025.)

UNE EN IEC 80601-2-71:2025

Medical electrical equipment - Part 2-71: Particular requirements for the basic safety and essential performance of functional near-infrared spectroscopy (NIRS) equipment (Endorsed by Asociación Española de Normalización in April of 2025.)

Equipos electromédicos. Parte 2-71: Requisitos particulares para la seguridad básica y funcionamiento esencial de los equipos funcionales de espectroscopia de infrarrojo cercano (NIRS) (Ratificada por la Asociación Española de Normalización en abril de 2025.)

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
2917 Kč
Anglicky Tisk
Skladem
2917 Kč
Označení normy:UNE EN IEC 80601-2-71:2025
Počet stran:66
Vydáno:2025-04-01
Status:Norma
Popis

UNE EN IEC 80601-2-71:2025

Clause 1 of the general standard1 applies, except as follows: 201.1.1 * Scope Replacement: This International standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of FUNCTIONAL NIRS EQUIPMENT, as defined in 201.3.205, intended to be used by itself, or as a part of an ME SYSTEM hereinafter referred to as ME EQUIPMENT. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020, 7.2.13 and 8.4.1. NOTE Additional information can be found in IEC 60601-1:2005, IEC 60601 1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020, 4.2. This document is not applicable to equipment for the measurement of oxygen saturation of the haemoglobin in the micro vessels (capillaries, arterioles and venules), i.e. tissue oximeters. frequency-domain and time-domain equipment for functional near-infrared spectroscopy. equipment for the measurement of changes in the concentration of chromophores other than oxy- and deoxy-haemoglobin. equipment for the measurement of changes in the concentration of oxy- and deoxy-haemoglobin in tissues other than the brain. This document does not specify the requirements for: cerebral tissue oximeter equipment, which are given in ISO 80601-2-85; and pulse oximeter equipment, which are given in ISO 80601-2-61. 201.1.2 Object Replacement: The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for FUNCTIONAL NIRS EQUIPMENT as defined in 201.3.205. NOTE 1 This document has been prepared to address the relevant ESSENTIAL PRINCIPLES and labelling[6] guidances of the International Medical Devices Regulators Forum (IMDRF) as indicated in Annex DD.

: