UNE EN ISO 80601-2-87:2021
Medical electrical equipment - Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilators (ISO 80601-2-87:2021) (Endorsed by Asociación Española de Normalización in June of 2021.)
Equipos electromédicos. Parte 2-87: Requisitos particulares para la seguridad básica y funcionamiento esencial de los ventiladores de alta frecuencia (ISO 80601-2-87:2021) (Ratificada por la Asociación Española de Normalización en junio de 2021.)
| Označení normy: | UNE EN ISO 80601-2-87:2021 |
| Počet stran: | 147 |
| Vydáno: | 2021-06-01 |
| Status: | Norma |
UNE EN ISO 80601-2-87:2021
This document applies to the basic safety and essential performance of a high-frequency ventilator (HFV) in combination with its accessories, hereafter referred to as ME equipment: ¯# intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility; NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment. High-frequency ventilators for this environment are considered life-sustaining. NOTE 2 For the purposes of this document, such a high-frequency ventilator can provide transport within a professional healthcare facility (i.e. be a transit-operable ventilator). NOTE 3 A high-frequency ventilator intended for use in transport within a professional healthcare facility is not considered as an ventilator intended for the emergency medical services environment. ¯# intended to be operated by a healthcare professional operator; ¯# intended for those patients who need differing levels of support from artificial ventilation including ventilator-dependent patients; and ¯# capable of providing more than 150 inflations/min. There are three principal designations of HFV: ¯# high frequency percussive ventilation (HFPV, with a typical HFV frequency of (60 to 1 000) HFV inflations/min); ¯# high frequency jet ventilation (HFJV, with a typical HFV frequency of (100 to 1 500) HFV inflations/min); and ¯# high frequency oscillatory ventilation (HFOV, with a typical HFV frequency of (180 to 1200) HFV inflations/min and typically having an active expiratory phase). Additionally, HFV designations can be combined together or with ventilation at rates less than 150 inflations/min. * A high-frequency ventilator is not considered to utilize physiologic closed loop-control system unless it uses a physiological patient variable to adjust the ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to an HFV breathing system, or to a high-frequency ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the high-frequency ventilator. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of IEC 60601-1:2005. NOTE 4 Additional information can be found in 4.2 of IEC 60601-1:2005+AMD1:2012. This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility. This document does not specify the requirements for: ¯# non-high-frequency ventilators or accessories which provide conventional ventilation for use in critical care environments, which are given in ISO 80601-2-12;. NOTE 5 An HFV can incorporate conventional critical care ventilator operational modes, in which case ISO 80601-2-12 is applicable to those modes. ¯# ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601-2-13 [3] 2; ¯# ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84, the future replacement for ISO 10651-3 [4]; NOTE 6 An HFV can incorporate EMS ventilator capability. ¯# ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72 [5]; ¯# ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79 [6] and ISO 80601-2-80 [7], the replacements for ISO 10651-6 [8]; ¯# sleep apnoea breathing therapy ME equipment, which are given in ISO 80601-2-70 [9]; ¯# continuous positive airway pressure (CPAP) ME equipment; ¯# oxygen therapy constant flow ME equipment; and ¯# cuirass or iron-lung ventilation equipment. This document is a particular standard in the IEC 60601 and IEC/ISO 80601 series of documents. 201.1.2 Object Replacement: The object of this document is to establish particular basic safety and essential performance requirements for a high-frequency ventilator, as defined in 201.3.201, and its accessories. NOTE 1 Accessories are included because the combination of the high-frequency ventilator and the accessories needs to be adequately safe. Accessories can have a significant impact on the basic safety or essential performance of a high-frequency ventilator. NOTE 2 This document has been prepared to address the relevant essential principles of safety and performance of ISO 16142-1:2016 as indicated in Annex CC. NOTE 3 This document has been prepared to address the relevant general safety and performance requirements of European regulation (EU) 2017/745 [10] as indicated in Annex DD.