Standard Test Method for Determination of Length Change of Concrete Due to Alkali-Silica Reaction

Měna
1 245 Kč
Označení normy:C1293-20A
Vydáno:01.06.2020
Status:Active
Počet stran:6
Sekce:04.02
Označení:aggregate; alkali-silica reactivity; concrete; length change; pozzolan; slag;
Popis

1.1 This test method covers the determination of the susceptibility of an aggregate or combination of an aggregate with pozzolan or slag for participation in expansive alkali-silica reaction by measurement of length change of concrete prisms.

1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard. When combined standards are cited, the selection of measurement system is at the user’s discretion subject to the requirements of the referenced standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2)

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.