Cena s DPH / bez DPH
Hlavní stránka>BS 1427:2009 Guide to on-site test methods for the analysis of waters
sklademVydáno: 2008-12-31
BS 1427:2009 Guide to on-site test methods for the analysis of waters

BS 1427:2009

Guide to on-site test methods for the analysis of waters

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9960 Kč
Anglicky Tisk
Skladem
9960 Kč
Označení normy:BS 1427:2009
Počet stran:128
Vydáno:2008-12-31
ISBN:978 0 580 59059 7
Status:Standard
Popis

BS 1427:2009


This standard BS 1427:2009 Guide to on-site test methods for the analysis of waters is classified in these ICS categories:
  • 13.060.01 Water quality in general

COMMENTARY ON 1.1.

Emergency screening analysis for major pollution incidents is not covered. Information on this is available via the US EPA which has set up an Environmental Technology Verification (ETV) Programme [1] and published a series of verification reports developed for each verified technology. The reports contain the performance verification test results and meet the ETV programme’s stringent quality assurance and peer review requirements for a wide range of advanced monitoring systems for water analysis mainly directed to emergency incidents. Further information on rapid analytical response issues in emergency situations is available (Thompson and O’Neill, 2006 [2] and Thompson, 2009 [3]).

This British Standard describes information and guidance on test methods for the analysis of industrial and other waters which are applicable outside of a conventional laboratory as either in situ on-site tests; or the use of a close suitable designated room/area testing facility. For some tests this could include dedicated space in a designated vehicle or caravan. These test methods can relate to compliance, water quality and process control purposes. No recommendation is given as to which test is applicable to a particular type of water, nor is it implied that in any given case all tests or any particular suite of tests are necessary. The selection of tests depends on local requirements and conditions. Samples requiring preservation for subsequent analysis are outside of the scope of this British Standard.

Certain tests such as adsorbable organic halides (AOX), chemical oxygen demand (COD), total organic carbon (TOC) and total nitrogen need a suitable designated test room/area facility and are not considered suitable for testing outside of these designated areas.

Sample stability is not considered to be a significant problem as most test-kit measurements are carried out with minimal delay.

Most of the methods described in this standard can be applicable for use on clean or lightly polluted waters which might have undergone treatment or been modified for industrial use. Typically, the types of waters for which the tests are intended include the following:

  1. boiler waters;

  2. cooling waters;

  3. waters from hot water systems;

  4. waters from air conditioning systems;

  5. waters from industrial air washing systems;

  6. potable waters;

  7. ground waters;

  8. surface waters;

  9. process waters; and

  10. swimming pool waters.

Certain more heavily polluted waters can be routinely tested for certain control purposes for specific determinands using the test methods cited in this British Standard. Such waters include:

  1. sewage works influents and effluents;

  2. selected industrial effluents.

Emergency screening analysis for major pollution incidents is not covered (see commentary).

The on-site methods outlined in this British Standard include titrimetric, colorimetric and instrumental analytical techniques and also includes consideration of commercial test-kits: their general principles and formats available. It is generally accepted that in the UK, the vast majority of on-site measurements are carried out using commercial test-kits rather than user-devised test-kit type methods following similar equivalent method procedures to those used in conventional laboratories. Also the designated room/area testing facility titrimetric methods described in Section 4 of this standard might require staff with a greater degree of training than commercial test-kit titrimetric methods which can be readily used outside of these areas. These methods are less likely to be used by non-analysts than the more robust test-kit titrimetric methods.

The technique used and principle of the designated room/area testing facility titrimetric method are described within each test method and each method is self-contained within a standard format.

This British Standard does not apply to radioactivity, ecotoxicity (See Persoone et al., 2000 [4]) or microbiological testing. Spot tests are not covered (Jungris, 1997 [5]).

Many of the relevant methods are suitable for analysis for the water framework directive (see Note and SWIFT 2003 [6]), water for human consumption (see Note) and for monitoring of discharges to water and sewer (EA, 2006 [7] and Dixon and Gardner, 1997 [8]).

NOTE EC 2000 [9] is known as ‘the water framework directive; EC 1998 [10], The Water Supply (Water Quality) Regulations 2000 [11] and DWI [12] relate to water for human consumption.