Cena s DPH / bez DPH
Hlavní stránka>BS 6955-13:1994 Calibration of vibration and shock pick-ups Method of test for base strain sensitivity
sklademVydáno: 1994-03-15
BS 6955-13:1994 Calibration of vibration and shock pick-ups Method of test for base strain sensitivity

BS 6955-13:1994

Calibration of vibration and shock pick-ups Method of test for base strain sensitivity

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
3780 Kč
Anglicky Tisk
Skladem
3780 Kč
Označení normy:BS 6955-13:1994
Počet stran:8
Vydáno:1994-03-15
ISBN:0 580 23085 6
Status:Standard
Popis

BS 6955-13:1994


This standard BS 6955-13:1994 Calibration of vibration and shock pick-ups is classified in these ICS categories:
  • 17.160 Vibrations, shock and vibration measurements

ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups.

This part of ISO 5347 lays down detailed specifications for the instrumentation and procedure to be used for base strain sensitivity testing. It applies to rectilinear accelerometers, mainly of the piezoelectric type.

This part of ISO 5347 is applicable for the following parameters:

  1. Reference values:
    • pick-up base radius of curvature: 25 m
    • base strain: 2,5 × 10−4
  2. Check values:
    • radius of curvature 62,5 m, strain of base 1 × 10−4
    • radius of curvature 12,5 m, strain of base 5 × 10−4