Hlavní stránka>BS 7835:2007 Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods
sklademVydáno: 2008-08-29
BS 7835:2007 Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods

BS 7835:2007

Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8700 Kč
Anglicky Tisk
Skladem
8700 Kč
Označení normy:BS 7835:2007
Počet stran:64
Vydáno:2008-08-29
ISBN:978 0 580 64040 7
Status:Corrigendum
Popis

BS 7835:2007


This standard BS 7835:2007 Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods is classified in these ICS categories:
  • 29.060.20 Cables

This British Standard specifies requirements and test methods for the construction, dimensions and mechanical and electrical properties of armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 (7.2) kV up to 19/33 (36) kV inclusive which, when assessed by the specified tests, produce lower levels of smoke and corrosive gases on exposure to fire compared to the cables specified in BS 6622. It covers cables designed for a maximum continuous conductor operating temperature of 90 °C and for a maximum short circuit conductor temperature of 250 °C, for use in fixed installations such as networks or industrial installations.

This British Standard specifies single-core and three-core cables for voltages in the range 3.8/6.6 (7.2) kV up to 19/33 (36) kV, with:

  • a stranded copper, stranded aluminium or solid aluminium conductor or conductors;
  • cross-linked polyethylene or cross-linked ethylene propylene rubber insulation;
  • a metallic screening layer of copper wire or copper tape and/or a metallic armour of aluminium or galvanized steel wire;
  • a thermoplastic oversheath.

NOTE Guidance on the selection of cables is given in Annex A. Information to be supplied by the purchaser, and items to be agreed between the purchaser and the manufacturer, at the time of enquiry and/or order, are given in Annex B. Recommendations for the installation of cables are given in Annex C. Guidance on the use of cables is given in Annex D.