Cena s DPH / bez DPH
Hlavní stránka>BS 8592:2016 Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification
sklademVydáno: 2016-03-31
BS 8592:2016 Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification

BS 8592:2016

Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4500 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
450.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1350.00 Kč
Anglicky Tisk
Skladem
4500 Kč
Označení normy:BS 8592:2016
Počet stran:22
Vydáno:2016-03-31
ISBN:978 0 580 90556 8
Status:Standard
Popis

BS 8592:2016


This standard BS 8592:2016 Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification is classified in these ICS categories:
  • 29.060.20 Cables

This British Standard specifies requirements and test methods for the construction and performance of non-armoured, single core non-sheathed cables which:

  1. have a thermosetting insulation of rated voltage 450/750 V;

  2. provide resistance to fire (circuit integrity), including mechanical shock, as measured by performance in a standard test;

  3. emit limited amounts of smoke and corrosive gases when burned as measured by a standard test;

  4. are flame retardant; and

  5. are primarily, but not exclusively, intended for use inside metal enclosures such as steel conduit.

This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings and similar applications, where maintenance of power supply during a fire is required for a defined period of time.

NOTE 1

Attention is drawn to the fact that the ability of a given cable to meet the test in this standard refers only to the test conditions stated, and the level of performance achieved in a particular installation can be influenced by actual installation conditions.

The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90 °C and for a maximum short-circuit conductor temperature of 250 °C (for a maximum of 5 s).

NOTE 2

Annex A gives recommendations for the selection, installation and operation of cables. Annex B gives notes on type tests.