Cena s DPH / bez DPH
Hlavní stránka>BS EN 14726:2019 Aluminium and aluminium alloys. Determination of the chemical composition of aluminium and aluminium alloys by spark optical emission spectrometry
sklademVydáno: 2019-03-21
BS EN 14726:2019 Aluminium and aluminium alloys. Determination of the chemical composition of aluminium and aluminium alloys by spark optical emission spectrometry

BS EN 14726:2019

Aluminium and aluminium alloys. Determination of the chemical composition of aluminium and aluminium alloys by spark optical emission spectrometry

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6240 Kč
Anglicky Tisk
Skladem
6240 Kč
Označení normy:BS EN 14726:2019
Počet stran:28
Vydáno:2019-03-21
ISBN:978 0 580 51677 1
Status:Standard
Popis

BS EN 14726:2019


This standard BS EN 14726:2019 Aluminium and aluminium alloys. Determination of the chemical composition of aluminium and aluminium alloys by spark optical emission spectrometry is classified in these ICS categories:
  • 77.120.10 Aluminium and aluminium alloys
  • 77.040.30 Chemical analysis of metals
This document describes the criteria and the procedure for analysing aluminium and aluminium alloys with spark optical emission spectrometry (S-OES). The scope of this document covers the following: - sample preparation; - operational guidelines for an optical emission spectrometer (including maintenance); - traceability of the analytical results to the International System of units: mass (kg); - assessing the uncertainty associated with each analytical result. This document refers to simultaneous spark emission spectrometers for the analysis of solid samples. It applies to the determination of silicon, iron, copper, manganese, magnesium, chromium, nickel, zinc, titanium, boron, gallium, vanadium, beryllium, bismuth, calcium, cadmium, cobalt, lithium, sodium, phosphorus, lead, antimony, tin, strontium and zirconium in aluminium and aluminium alloys. Elements other than those listed above may be analysed on the condition that: a) suitable reference materials are available; and b) the instrument is suitably calibrated and equipped. In the case of determining mercury, for compliance purposes an alternate method with a limit of quantification < 0,000 1 % is recommended as its detection is compromised by intense iron interference at 253,65 nm. The test result obtained from a spark optical emission spectrometer generally concerns an amount of less than one milligram per spark spot. The result can be used to refer to the laboratory test sample, to the aluminium or aluminium alloy melt or to the cast product.