Cena s DPH / bez DPH
Hlavní stránka>BS EN 16905-5:2022 - TC Tracked Changes. Gas-fired endothermic engine driven heat pumps Calculation of seasonal performances in heating and cooling mode
sklademVydáno: 2023-01-25
BS EN 16905-5:2022 - TC Tracked Changes. Gas-fired endothermic engine driven heat pumps Calculation of seasonal performances in heating and cooling mode

BS EN 16905-5:2022 - TC

Tracked Changes. Gas-fired endothermic engine driven heat pumps Calculation of seasonal performances in heating and cooling mode

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
11340 Kč
Anglicky Tisk
Skladem
11340 Kč
Označení normy:BS EN 16905-5:2022 - TC
Počet stran:146
Vydáno:2023-01-25
ISBN:978 0 539 25592 8
Status:Tracked Changes
Popis

BS EN 16905-5:2022 - TC


This standard BS EN 16905-5:2022 - TC Tracked Changes. Gas-fired endothermic engine driven heat pumps is classified in these ICS categories:
  • 27.080 Heat pumps
This part of EN 16905 specifies the calculation of the seasonal performance factor for gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoors. This document only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions. This document only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021. This document only applies to appliances having: a) gas fired endothermic engines under the control of fully automatic control systems; b) closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated; c) where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the: 1) heating water circuit (if installed) does not exceed 6 bar, 2) domestic hot water circuit (if installed) does not exceed 10 bar. This document applies to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery. This document is applicable to GEHP appliances that are intended to be type tested. Requirements for GEHP appliances that are not type tested would need to be subject to further consideration.