Cena s DPH / bez DPH
Hlavní stránka>BS EN 61995-1:2008+A1:2017 Devices for the connection of luminaires for household and similar purposes General requirements
sklademVydáno: 2018-03-09
BS EN 61995-1:2008+A1:2017 Devices for the connection of luminaires for household and similar purposes General requirements

BS EN 61995-1:2008+A1:2017

Devices for the connection of luminaires for household and similar purposes General requirements

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8700 Kč
Anglicky Tisk
Skladem
8700 Kč
Označení normy:BS EN 61995-1:2008+A1:2017
Počet stran:70
Vydáno:2018-03-09
ISBN:978 0 580 84072 2
Status:Standard
Popis

BS EN 61995-1:2008+A1:2017


This standard BS EN 61995-1:2008+A1:2017 Devices for the connection of luminaires for household and similar purposes is classified in these ICS categories:
  • 29.120.20 Connecting devices
  • 29.140.40 Luminaires

This part of IEC 61995 applies to devices for the connection of luminaires (DCL) intended for household and similar purposes, for the electrical connection of fixed luminaires of class I or class II to final circuits rated at not more than 16 A without providing a mechanical support for the luminaire. DCLs are intended for use according to their IP rating as specified in IEC 60529.

Outlets have an earthing contact and a rated current of 6 A. Plugs have a rated current of 6 A.

The rated voltage is 125 V or 250 V at 50/60 Hz.

NOTE 1 This standard does not cover integrated DCL-plugs (under consideration).

This standard can also be applied to types other than those with standardised interface.

NOTE 2 In the following countries only types with a standardised interface according to IEC 61995-2 (under consideration) are allowed: IT.

DCL plugs and DCL outlets complying with this standard are suitable for use under the following conditions:

  • an ambient temperature not normally exceeding 25 °C, but occasionally reaching 35 °C;

    NOTE 3 The effect of the heat generated by the luminaire may affect the ambient temperature local to the DCL.

  • a temperature not exceeding 70 °C at the terminals of the DCL outlet including the effect of heat generated by the luminaire and the passage of current.

    NOTE 4 The requirements and tests of this standard may also be used as a guide when testing DCL's which have different interface configurations or ratings.