Hlavní stránka>PD CEN ISO/TR 22930-2:2021 Evaluating the performance of continuous air monitors Air monitors based on flow-through sampling techniques without accumulation
sklademVydáno: 2021-09-07
PD CEN ISO/TR 22930-2:2021 Evaluating the performance of continuous air monitors Air monitors based on flow-through sampling techniques without accumulation

PD CEN ISO/TR 22930-2:2021

Evaluating the performance of continuous air monitors Air monitors based on flow-through sampling techniques without accumulation

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7320 Kč
Anglicky Tisk
Skladem
7320 Kč
Označení normy:PD CEN ISO/TR 22930-2:2021
Počet stran:42
Vydáno:2021-09-07
ISBN:978 0 539 17590 5
Status:Corrigendum
Popis

PD CEN ISO/TR 22930-2:2021


This standard PD CEN ISO/TR 22930-2:2021 Evaluating the performance of continuous air monitors is classified in these ICS categories:
  • 13.280 Radiation protection

The use of a continuous air monitor (CAM) is mainly motivated by the need to be alerted quickly and in the most accurate way possible with an acceptable false alarm rate when significant activity concentration value is exceeded, in order to take appropriate measures to reduce exposure of those involved.

The performance of this CAM does not only depend on the metrological aspect characterized by the decision threshold, the limit of detection and the measurement uncertainties but also on its dynamic capacity characterized by its response time as well as on the minimum detectable activity concentration corresponding to an acceptable false alarm rate.

The ideal performance is to have a minimum detectable activity concentration as low as possible associated with a very short response time, but unfortunately these two criteria are in opposition. It is therefore important that the CAM and the choice of the adjustment parameters and the alarm levels be in line with the radiation protection objectives.

This document describes

  • the dynamic behaviour and the determination of the response time,

  • the determination of the characteristic limits (decision threshold, detection limit, limits of the coverage interval), and

  • a possible way to determine the minimum detectable activity concentration and the alarms setup.

Finally the annexes of this document show actual examples of CAM data which illustrate how to quantify the CAM performance by determining the response time, the characteristics limits, the minimum detectable activity concentration and the alarms setup.