Cena s DPH / bez DPH
>UNE EN 15182-1:2020 - Portable equipment for projecting extinguishing agents supplied by firefighting pumps - Hand-held branchpipes for fire service use - Part 1: Common requirements
sklademVydáno: 2020-02-19
UNE EN 15182-1:2020 - Portable equipment for projecting extinguishing agents supplied by firefighting pumps - Hand-held branchpipes for fire service use - Part 1: Common requirements

UNE EN 15182-1:2020

Portable equipment for projecting extinguishing agents supplied by firefighting pumps - Hand-held branchpipes for fire service use - Part 1: Common requirements

Equipo portátil para proyectar agentes extintores suministrados por bombas de extinción de incendios. Lanzas de manguera manuales destinadas a los servicios contra incendios. Parte 1: Requisitos comunes.

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
2333 Kč
Anglicky Tisk
Skladem
2333 Kč
Španělsky PDF
K okamžitému stažení
Tisknutelné
2333 Kč
Španělsky Tisk
Skladem
2333 Kč
Označení normy:UNE EN 15182-1:2020
Počet stran:31
Vydáno:2020-02-19
Status:Norma
Počet stran (Španělsky):32
Popis

UNE EN 15182-1:2020

This document applies to hand-held branchpipes. It deals with: safety requirements; performance requirements; test methods; classification and designation; instructions for use and maintenance; marking. It is advised to read this document in conjunction with parts 2, 3 or 4. This document does not apply to branchpipes covered by EN 671, foam branchpipes covered by EN 16712-3, powder branchpipes, or branchpipes with a maximum working pressure above 40 bar. NOTE 1 The Working Group has thoroughly addressed and discussed the issue of electrical safety in relation to using water branchpipes. However, an electrical test is not incorporated into this document as international experience, as well as research (NFPA handbook, French research, etc) have shown that any "artificial" or "laboratory style" testing will not take into account poor visibility and other conditions present on any fireground, nor the problem of estimating distances under these conditions. The end user is advised (through the operating instructions, see 8.1) that when fighting fires in or near electrical installations, the power should be cut off as soon as possible. Also, it is advised to maintain a maximum possible safety distance (at least 1 m up to 1 000 V) and to use a spray jet with a minimum spray angle of 30 °. NOTE 2 It is essential to take into account reaction forces into consideration before choosing and operating branchpipes.

: