Cena s DPH / bez DPH
>UNE EN 50306-4:2020 - Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair screened or not screened sheathed cables
sklademVydáno: 2020-10-14
UNE EN 50306-4:2020 - Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair screened or not screened sheathed cables

UNE EN 50306-4:2020

Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair screened or not screened sheathed cables

Aplicaciones ferroviarias. Cables para material rodante ferroviario con un comportamiento especial ante el fuego. Capa aislante delgada. Parte 4: Cables multiconductores y multipares con cubierta, apantallados o no apantallados.

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
2982 Kč
Anglicky Tisk
Skladem
2982 Kč
Španělsky PDF
K okamžitému stažení
Tisknutelné
2485 Kč
Španělsky Tisk
Skladem
2485 Kč
Označení normy:UNE EN 50306-4:2020
Počet stran:33
Vydáno:2020-10-14
Status:Norma
Počet stran (Španělsky):37
Popis

UNE EN 50306-4:2020

This document specifies requirements for, and constructions and dimensions of, multicore and multipair cables rated voltage Uo/U: 300/500 V, of the following types: unscreened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 48); screened, sheathed for either exposed or protected wiring (0,5 mm2 to 2,5 mm2, number of cores from 2 to 8); unscreened, sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of screened pairs of cores from 2 to 7). screened, sheathed for either exposed or protected wiring (0,5 mm2 to 1,5 mm2, number of unscreened pairs of cores from 2 to 7). All cables have stranded tinned copper conductors, halogen-free, thin wall thickness insulation and standard wall thickness sheath. Cable types are specified for use in exposed situations (Class E), and for protected situations (Class P). They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 90 °C. For standard cables this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5000h) thermal ageing indicating a 110 °C/20 000 h temperature index. Should the customer require lifetime predictions this should be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545-1 and EN 45545-2. prEN 50306-4:2014 has to be used in conjunction with prEN 50306-1:2018, General requirements, prEN 50306-2:2018, Single core cables, and prEN 50306-3:2018, Single core and multicore cables.

: