Cena s DPH / bez DPH
>UNE EN 50518:2020 - Monitoring and alarm receiving centre
sklademVydáno: 2020-07-22
UNE EN 50518:2020 - Monitoring and alarm receiving centre

UNE EN 50518:2020

Monitoring and alarm receiving centre

Centro de supervisión y recepción de alarmas.

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
3069 Kč
Anglicky Tisk
Skladem
3069 Kč
Španělsky PDF
K okamžitému stažení
Tisknutelné
3069 Kč
Španělsky Tisk
Skladem
3069 Kč
Označení normy:UNE EN 50518:2020
Počet stran:47
Vydáno:2020-07-22
Status:Norma
Počet stran (Španělsky):56
Popis

UNE EN 50518:2020

This European Standard specifies the minimum requirements for monitoring, receiving and processing of alarm messages generated by alarm systems taking place as an integrated part of the total fire safety and security solution. For the purpose of this standard, the term alarm is used in the broad sense to include fault, status and other messages received from one or more of a range of safety and security alarm systems such as but not limited to fire detection and fire alarm systems, fixed fire fighting systems, intrusion and hold-up alarm systems, access control systems, video surveillance systems, social alarms systems and combinations of such systems. This standard gives requirements for two categories of ARC, category I and category II. A category I ARC will be designed, constructed and operated to a higher standard with respect to construction, security and integrity than a category II ARC. The categorization is determined according to the type(s) of alarm messages handled. Category I: ARCs handling messages from: " I&HAS s; " access control systems; " VSS in security applications that require an emergency response (for example loss prevention); " people monitoring and object tracking systems for security applications; " alarm messages handled by category II ARCs; " combinations of the above systems. Category II: ARC s handling messages from: " fire alarm systems; " fixed firefighting systems; " social alarm systems; " audio/video door entry systems; " VSS in non-security applications (for example traffic flow); " people monitoring and object tracking systems for non-security applications; " elevator emergency systems; " combinations of the above systems. The requirements apply to ARC s (whether established in single or multiple sites) monitoring and processing alarms generated by systems installed at other locations and also to ARC s monitoring solely alarms from systems within their own site. The standard includes functional and specific requirements supporting the services of an ARC. The standard does NOT apply to " alarm systems used for non-civil purposes; " alarm systems for medical or health applications.

: