Cena s DPH / bez DPH
>UNE EN IEC 61326-3-2:2018 - Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment (Endorsed by Asociación Española de Normalización in January of 2019.)
sklademVydáno: 2019-01-01
UNE EN IEC 61326-3-2:2018 - Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment (Endorsed by Asociación Española de Normalización in January of 2019.)

UNE EN IEC 61326-3-2:2018

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment (Endorsed by Asociación Española de Normalización in January of 2019.)

Material eléctrico para medida, control y uso en laboratorio. Requisitos de compatibilidad electromagnética (CEM). Parte 3-2: Requisitos de inmunidad para los sistemas relativos a la seguridad y para los equipos previstos para realizar funciones relativas a la seguridad (seguridad funcional). Aplicaciones industriales con entorno electromagnético especificado. (Ratificada por la Asociación Española de Normalización en enero de 2019.)

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
2543 Kč
Anglicky Tisk
Skladem
2543 Kč
Označení normy:UNE EN IEC 61326-3-2:2018
Počet stran:48
Vydáno:2019-01-01
Status:Norma
Popis

UNE EN IEC 61326-3-2:2018

This part of IEC 61326 covers all equipment within the scope of IEC 61326-1, but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, and based on the requirements of the process industry, specifically chemical/petrochemical/pharmaceutical manufacturing plants using the mitigation measures given in Annex C. The difference between the electromagnetic environment covered by this standard compared to the general industrial environment (see IEC 61326-3-1) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment with test values that have been proven in practice. The environment of industrial application with a specified electromagnetic environment typically includes the following characteristics: industrial area with limited access; limited use of mobile transmitters; dedicated cables for power supply and control, signal or communication lines; separation between power supply and control, signal or communication cables; factory building mostly consisting of metal construction; overvoltage/lightning protection by appropriate measures (for example, metal construction of the building or use of protection devices); pipe heating systems driven by a.c. main power; no high-voltage substation close to sensitive areas; presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with low power; competent staff; periodical maintenance of equipment and systems; mounting and installation guidelines for equipment and systems. Equipment and systems considered as proven-in-use according to IEC 61508 or prior use according to IEC 61511 are excluded from the scope of IEC 61326-3-2. Fire alarm systems and security alarm systems intended for protection of buildings are excluded from the scope of IEC 61326-3-2.

: