Cena s DPH / bez DPH
>UNE EN IEC 62271-214:2021 - High-voltage switchgear and controlgear - Part 214: Internal arc classification for metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
sklademVydáno: 2021-05-05
UNE EN IEC 62271-214:2021 - High-voltage switchgear and controlgear - Part 214: Internal arc classification for metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

UNE EN IEC 62271-214:2021

High-voltage switchgear and controlgear - Part 214: Internal arc classification for metal-enclosed pole-mounted switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

Aparamenta de alta tensión. Parte 214: Clasificación de arco interno para aparamenta montada en poste para tensiones nominales superiores a 1 kV e inferiores o iguales a 52 kV.

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
2659 Kč
Anglicky Tisk
Skladem
2659 Kč
Španělsky PDF
K okamžitému stažení
Tisknutelné
2659 Kč
Španělsky Tisk
Skladem
2659 Kč
Označení normy:UNE EN IEC 62271-214:2021
Počet stran:39
Vydáno:2021-05-05
Status:Norma
Počet stran (Španělsky):42
Popis

UNE EN IEC 62271-214:2021

This part of IEC 62271 specifies requirements for internal arc classification of metal enclosed pole-mounted switchgear installations used for alternating current with rated voltages above 1 kV and up to and including 52 kV with service frequencies up to and including 60 Hz. This standard is applicable to three-phase, two phase and single phase equipment. Enclosures may include fixed and removable components and may be filled with fluid (liquid or gas) to provide insulation. NOTE 1 For the use of this document high-voltage (IEC 60050-601:1985, 601-01-27) is the rated voltage above 1 000 V. However, medium voltage (IEC 60050-601:1985, 601-01-28) is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV; refer to [1] of Bibliography. This standard does not preclude that other equipment may be included in the same enclosure. In such a case, any possible influence of that equipment on the switchgear and controlgear is to be taken into account.

: