Cena s DPH / bez DPH
>UNE EN ISO 14501:2022 - Milk and milk powder - Determination of aflatoxin M1 content - Clean-up by immunoaffinity chromatography and determination by high-performance liquid chromatography (ISO 14501:2021)
sklademVydáno: 2022-05-04
UNE EN ISO 14501:2022 - Milk and milk powder - Determination of aflatoxin M1 content - Clean-up by immunoaffinity chromatography and determination by high-performance liquid chromatography (ISO 14501:2021)

UNE EN ISO 14501:2022

Milk and milk powder - Determination of aflatoxin M1 content - Clean-up by immunoaffinity chromatography and determination by high-performance liquid chromatography (ISO 14501:2021)

Leche y leche en polvo. Determinación del contenido de aflatoxina M1. Purificación mediante cromatografía de inmunoafinidad y determinación mediante cromatografía líquida de alta resolución. (ISO 14501:2021).

Formát
Dostupnost
Cena a měna
Anglicky PDF
K okamžitému stažení
Tisknutelné
1988 Kč
Anglicky Tisk
Skladem
1988 Kč
Španělsky PDF
K okamžitému stažení
Tisknutelné
1988 Kč
Španělsky Tisk
Skladem
1988 Kč
Označení normy:UNE EN ISO 14501:2022
Počet stran:20
Vydáno:2022-05-04
Status:Norma
Popis

UNE EN ISO 14501:2022

This document specifies a method for the determination of aflatoxin M1 content in milk and milk powder. The lowest level of validation is 0,08 ¼g/kg for whole milk powder i.e. 0,008 ¼g/l for reconstituted liquid milk. The limit of detection (LOD) is 0,05 ¼g/kg for milk powder and LOD is 0,005 ¼g/kg for liquid milk. The limit of quantification(LOQ) is 0,1 ¼g/kg for milk powder and LOQ is 0,01 ¼g/kg for liquid milk. The method is also applicable to low fat milk, skimmed milk, low fat milk powder and skimmed milk powder. CAUTION 1 The method described in this protocol requires the use of solutions of aflatoxin M1. Aflatoxins are carcinogenic to humans. Attention is drawn to the statement made by the International Agency for Research on Cancer (WHO)[1,2]. CAUTION 2 Protect the laboratory in which the analyses are performed adequately from daylight and keep aflatoxin standard solutions protected from light, e.g. by using aluminium foil. CAUTION 3 The use of non-acid-washed glassware (e.g. tubes, vials, flasks, beakers, syringes) for aqueous aflatoxin solutions may cause loss of aflatoxin. Moreover, brand new laboratory glassware, before coming into contact with aqueous solutions of aflatoxin, should be soaked in dilute acid (e.g. sulfuric acid, 2 mol/l) for several hours, then rinsed well with distilled water to remove all traces of acid (check to ensure pH is in the range 6 to 8). CAUTION 4 Use decontamination procedures for laboratory wastes such as solid compounds, solutions in organic solvents, aequeous solutions and spills, and for glassware coming into contact with carcinogenic materials. Suitable decontamination procedures have been developed and validated by the International Agency for Research on Cancer (WHO)[1,2].

: